Transformer

This device is a device that changes the value of AC voltage or current to the desired value using electromagnetic induction through dry and inflow type, and is manufactured by ordering from small to large capacity.

Isolation Transformer Comparison

Name Structure characteristic
Insulating
Transformer
The primary and secondary coils are completely separated and wound to prevent voltage current from being directly connected to the secondary side The first and second rounds are completely separated.a lack of prospects
Shield
Transformer
A capacitive shielding plate is attached between  the primary and secondary windings to prevent high frequency (noise) in the voltage current from being induced to the secondary through the distribution capacity on the primary side The first and second parts are separated.There is no electrostatic coupling
Noise cut
Transfotmer
A  multi-coated electronic shield plate is installed outside the coil and the transformer, and  the magnetic flux of the core and coil does not cross between coils to prevent conduction of noise by electromagnetic induction. The primary and secondary are separated, there is no electrostatic coupling, and there is no high-frequency electromagnetic induction.
Insulation transformer a shielded transformer Interference wave cut-off transformer
*Normal Mode and
Comom Mode
both Noise pass
Normal Mode passes.
Com Mode frequency isIt prevents the lower part.Pass the high part.
Prevent both Normal Mode and Com Mode
Normal Mode Noise Normal Mode Noise Normal Mode Noise
Comom Mode Noise Comom Mode Noise Comom Mode Noise
Above: Primary side voltage waveform (Noise mixed)
Below: Secondary side voltage waveform (Secondary side induction  state)  *Measurement: Y axis 100V/divX axis 1ms/div
Above: Primary side voltage waveform (Noise mixed)
Below: Secondary side voltage waveform (Secondary side induction  state) 
*Measurement: Y axis 100V/divX axis 1ms/div
Above: Primary side voltage waveform (Noise mixed)
Below: Secondary voltage waveform ( clean secondary status ) 
*Measurement; Y axis 100V/divX axis 1ms/div

Isolation Transformer production model and size

Formality Model Capacity Size (mm)
(W x D x H)
Monophastic
ISOLATION
T/R Type
OT 1253 1Ø 1KVA 350 x 370 x 220
OT 1253S
OT 1253L
OT 1263 1Ø 2KVA
OT 1263S
OT 1263L
OT 1276 1Ø 3KVA 270 x 470 x 500
OT 1276S
OT 1276L
OT 12AG 1Ø 5KVA
OT 12AGS
OT 12AGL
OT 12CE 1Ø 7.5KVA 340 x 530 x 580
OT 12CES
OT 12CEL
OT 12EE 1Ø 10KVA
OT 12EES
OT 12EEL
OT 12GM 1Ø 15KVA 400 x 630 x 680
OT 12GMS
OT 12GML
OT 12IM 1Ø 20KVA
OT 12IMS
OT 12IML
OT 12KT 1Ø 25KVA 400 x 460 x 740
OT 12KTS
OT 12KTL
OT 12MT 1Ø 30KVA
OT 12MTS
OT 12MTL
OT 12OU 1Ø 40KVA 440 x 750 x 1000
OT 12OUS
OT 12OUL
OT 12Qa 1Ø 50KVA
OT 12QaS
OT 12QaL
OT 12Ui 1Ø 75KVA 600 x 900 x 1500
OT 12UiS
OT 12UiL
OT 12Mi 3Ø 100KVA
OT 12MiS
OT 12MiL
OT 12Ui 1Ø 150KVA
OT 12UiS
OT 12UiL

* OT 12ㅁㅁS는 SAFETY(산업 안전 표시) 1Ø 제품임
* OT 12ㅁㅁL은 NCT형 T/R 1Ø 제품임

Isolation Transformer’s production model and size

Formality Model Capacity Size (mm)
(W x D x H)
Triphastic
ISOLATION
T/R Type
OT 34CK 3Ø 7.5KVA 400 x 460 x 740
OT 34CKS
OT 34CKL
OT 34EO 3Ø 10KVA
OT 34EOS
OT 34EOL
OT 34GW 3Ø 15KVA
OT 34GWS
OT 34GWL
OT 34IW 3Ø 20KVA
OT 34IWS
OT 34IWL
OT 33KX 3Ø 25KVA
OT 33KXS
OT 33KXL
OT 34MX 1Ø 10KVA
OT 34MXS
OT 34MXL
OT 33NX 3Ø 35KVA 440 x 750 x 1000
OT 33NXS
OT 33NXL
OT 33Oj 3Ø 40KVA
OT 33OjS
OT 33OjL
OT 33Pj 3Ø 45KVA
OT 33PjS
OT 33PjL
OT 33Qj 3Ø 50KVA
OT 33QjS
OT 33QjL
OT 34Sj 3Ø 60KVA
OT 34SjS
OT 34SjL
Formality Model Capacity Size (mm)
(W x D x H)
Triphastic
ISOLATION
T/R Type
OT 34Uj 3Ø 75KVA 600 x 900 x 1500
OT 34UjS
OT 34UjL
OT 34Wn 3Ø 100KVA
OT 34WnS
OT 34WnL
OT 33Yn 3Ø 120KVA
OT 33YnS
OT 33YnL
OT 33an 3Ø 150KVA
OT 33anS
OT 33anL
OT 34fu 3Ø 200KVA 700 x 900 x 1600
OT 34fuS
OT 34fuL
OT 34Hu 3Ø 250KVA
OT 34HuS
OT 34HuL
OT 34ju 3Ø 300KVA
OT 34juS
OT 34juL

* OT 3ㅁㅁㅁS is SAFETY(Occupational Safety Marks) 3Ø product
* * OT 3ㅁㅁL is a NCT type T/R 3 Ø product