TRS®
Single-phase uninterruptible power supply

Highly functionalization of TRS® TYPE!

Silent demonstration with state-of-the-art UPST with synchronous switching function using Korea’s first IGBT  device

overview

This product is an uninterruptible power supply  TRS series with  synchronous switching supply, and it is  an inverter control method using IGBT, a state-of-the-art device. The inverter  control configuration has a frequency control range of  20kHz  or more, and it is a state-of-the-art circuit that has a synchronous switchover function in the event of  a fault or an overload and an abnormality in the load (withstands the load  short), and has a function of   shut-down if the  short of the load is not canceled even in this state.
This control method has been a problem of other  types of UPSs, such as the synchronous switching function · Noise · Instantaneous blackouts · Low efficiency ·  It is a breakthrough product that completely improves unstable voltages.

feature

This UPS is divided into TRS100, TRS502, TRS701, and TRS800 types.
The configuration consists of a  converter, battery charger, inverter, filter, base driver, static switch, and main control PCB, and the PWM control range is more than  20kHz, and there is almost no noise, and the efficiency is high due to  the SMPS-type  design of the live part, and there is a static function in high-frequency PWM control. It has the characteristics of constant voltage,
sine wave, and constant frequency in normal operation, and the  LED is indicated in case of fault, and the cooling FAN operates according to the state of temperature.  The
front panel  is divided into Digital Type, LCD (Micro Processor) Type, and FND Type according to the user’s convenience. In addition, it is small in size and produces almost no noise compared to the size of the same capacity, so it is easy to install even in small places.

Display function

  • Online method

  • Pager Function (TRS800)

  • Constant voltage, constant frequency, sine wave output

  • Auto Shut-Down function

  • Digital Control Method

  • Overload protection cabinet

  • Green Model function(TRS 800)

  • Net-work Remote Monitoring (TRS800)

  • UPS history auto-save

  • Auto Fan Driven Corrosion

  • Maintenance device interior

Schematic diagram

Protection of TRS Type

Input overvoltage and undervoltage protection characteristics
 – Buzzer alarm (cuts off input voltage, protects the instrument)

Output overcurrent protection characteristic
 – Static operation over 120% of the rated output current to switch  by pass
–  Inverter transfer at By pass at normal load with   rated output current of 100%  or less

Temperature protection
 – In the event of an overtemperature due to an abnormality in the FAN function, the power supply from the inverter to the By Pass
– When the overtemperature occurs above  80°C
 in the peninsula stay,  the power supply from the  inverter to the By Pass  

Battery protection
 – SMPS configuration for improved precision
 – constant voltage · Constant current charging prevents overcharging
 – DC low monitoring device prevents over-discharge

Output overvoltage and undervoltage protection characteristics
– When the  rated voltage fluctuates by more than ±10% due to failure or abnormality of the inverter unit, it is switched by pass

Remote derivation using DIAL MODEM  communication

feature

Remote control and monitoring function A function to monitor and control the
 operation status of the  UPS using a  PC with a monitoring function using RS232/C
– A function to monitor the  UPS
through remote communication using a modem
– Network management
 function (SNMP)

Dial Modem function
– Auto Dial function
–  Redial  function to automatically call back when the administrator is on a call (phone)
–  Automatic call function (built-in Pager function) (landline phone/mobile phone/pager/e-mail transmission, text message and call function)

Standard specifications and features

Capacity (VA) 10K~15KVA 20K~30KVA 40K~50KVA
Standing history
Number of constants 1 phase 2 wire
Input voltage 220V AC ±10% (standard)
The number of waves 60㎐ ±5%
DC voltage 210V DC 264V DC
Dispatch peculiarities
Number of constants 1 phase 2 wire
Output voltage 220V AC(standard)
Anjeongdo ±2%
Waveform Sine wave type
Control method IGBT(PWM control)
Why Yule ±3%(at linear load)
Load power factor 0.8(ground)
Overload tolerance 125% – 10 minutes / 150% – 1 minute
Cattle Within 65dB
Efficacy > more than 85%
Discipline
Number of constants 1 phase 2 wire
The number of waves 60㎐
Overload tolerance 150% – 1 minute
Cut-off time Within 4 ms
Absolute conditions Battery voltage / overload / overtemperature / equipment failure / manual stop
Ability
Kick short-term Input/output/battery/maintenance
Display function Input, output voltage/current/frequency, accumulator voltage, inverter
ON/OFF, alarm stop system history and failure history storage

* Note: TRS specifications and sizes for each model are indicated, so you need to select them when purchasing.